Capnocheck® Capnometer - Smiths Medical
Capnocheck® Capnometer - Smiths Medical
Capnocheck® Capnometer - Smiths Medical
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Capnocheck ®<br />
PATienT MoniTorinG<br />
<strong>Capnometer</strong><br />
The BCi ® Capnocheck ®<br />
Capno meter is a small portable<br />
quantitative capnometer<br />
that monitors carbon dioxide<br />
concentrations and respiratory<br />
rate in one easy to use device<br />
that can be used for<br />
• Intubation verification<br />
• Return of spontaneous<br />
circulation during CPR<br />
• Routine airway management<br />
• Transport<br />
• Ventilator weaning<br />
Unlike colorimetric and other<br />
qualitative mechanical devices,<br />
the Capnocheck ® <strong>Capnometer</strong><br />
provides a fully quantitative value<br />
that is now recommended in the<br />
AHA 2005 guidelines. During<br />
resuscitation, the Capnocheck ®<br />
<strong>Capnometer</strong> can be an effective<br />
noninvasive indicator of cardiac<br />
output, and return of spontaneous<br />
circulation. The simple operation<br />
and accuracy of the Capnocheck ®<br />
<strong>Capnometer</strong> make it an invaluable<br />
tool in all areas of clinical practice.<br />
For more information, visit<br />
smiths-medical.com/capnocheck.
Alarm Silence Button (WW8110-001 only)<br />
Alarm Status Indicator<br />
(not illuminated)<br />
Breath Indicator Bar<br />
Battery Status Indicator<br />
Power Button<br />
BCi ®<br />
Capnocheck ®<br />
<strong>Capnometer</strong><br />
The ultra-compact Capnocheck ® <strong>Capnometer</strong> makes monitoring<br />
patients' ETCO 2 easy, efficient, and dependable.<br />
• Intuitive to use<br />
• Fully quantitative<br />
• Miniaturized mainstream device<br />
• Pocket size and lightweight (2.1 oz)<br />
• Battery powered – 2 AAA for<br />
continuous operation up to<br />
8 hours<br />
Ventilator Circuit VR1 Emergency and Transport Ventilator<br />
Bag Valve Mask<br />
examples of ventilation Sources<br />
Examples of Airway Connections<br />
Endotracheal Tube Mask<br />
Respiratory Rate Value<br />
Airway Adapter<br />
• No calibration required<br />
• No warm-up time<br />
• Two versions available –<br />
with or without alarms<br />
• Lightweight, small,<br />
easy storage<br />
ETCO 2 Value<br />
Laryngeal Mask
The Capnocheck ®<br />
<strong>Capnometer</strong>’s<br />
miniature size is proven in the<br />
most critical scenarios<br />
evaluate<br />
• Provides immediate information of respiratory status<br />
• Routine assessment of ventilation<br />
• Non-invasive assessment of respiratory status with mouthpiece<br />
• Validation and assessment of therapies and treatments<br />
• Use with mask or artificial airway<br />
resuscitate<br />
• Verification/Confirmation of tracheal intubation<br />
• Early indicator of return of spontaneous circulation<br />
(ROSC) during CPR<br />
• Informs the clinician of the effectiveness of cardiac<br />
compressions<br />
• Meets AHA 2005 Guidelines indicating that end-tidal CO 2<br />
monitoring is a safe and effective noninvasive indicator of<br />
cardiac output during CPR and may be an early indicator<br />
of ROSC in intubated patients<br />
Transport<br />
• Increases safety during patient transports by<br />
facilitating the integrity of an ET tube<br />
• Provides an indication of adequate ventilation<br />
• Helps monitor airway during patient movement<br />
ventilate<br />
• Assists in ongoing and routine assessment of ventilation<br />
(Helping to reduce the number of routine arterial blood gases)<br />
• Monitors the adequacy of ventilation during ventilator weaning<br />
• Early indicator of respiratory muscle failure<br />
<strong>Smiths</strong> <strong>Medical</strong> also provides a full-featured solution for emergency<br />
and transport ventilation resuscitation<br />
Pneupac ® VR1 Emergency and Transport Ventilator<br />
• Small, lightweight design has all the advantages of<br />
portability without compromising key clinical features<br />
• Auto/manual control allows the operator to choose<br />
automatic mode or to provide ventilation manually<br />
• Integrated patient demand system allows synchronized<br />
interaction with the patient’s own breathing efforts<br />
• Available with and without airmix
Capnocheck ®<br />
<strong>Capnometer</strong><br />
Technical Specifications<br />
• Description<br />
Pocket size, battery powered, quantitative<br />
capnometer for mainstream CO2 monitoring<br />
of adults and pediatrics<br />
• Measurements<br />
Non-dispersive IR absorption<br />
• Models<br />
Capnocheck ® WW8110-000<br />
Capnocheck ® with alarms WW8110-001<br />
• Warm Up<br />
Operational to full specification within 5 sec.<br />
• Calibration<br />
No routine calibration required<br />
• Certifications<br />
93/42/EEC and UL/CSA 60601-1<br />
• Dimensions<br />
2.1 x 1.5 x 1.5 inches (52 x 39 x 39 mm)<br />
• Weight<br />
2.1 oz (60 g) with batteries<br />
• Shock Absorption<br />
Withstands repeated 1 m drops<br />
PoWer reqUireMenTS<br />
• Batteries<br />
Two (2) AAA cell alkaline batteries (2 x 1.5VDC)<br />
(IEC Type LR03); 8 hour normal operation<br />
• Power Status<br />
LED Indicator<br />
environMenTAl<br />
• Operating Conditions<br />
Temperature: 23°F to 122°F (-5°C to +50°C)<br />
Humidity: 10 - 95% RH (non-condensing)<br />
Atmospheric Pressure: 70 - 120 kPa<br />
• Storage Conditions<br />
Temperature: -22°F to +158°F<br />
(-30°C to +70°C)<br />
Humidity: 5 - 100% RH (condensing)<br />
Atmospheric Pressure: 50 - 120 kPa<br />
DiSPlAYS<br />
• ETCO 2<br />
LED Numeric Display<br />
• Respiratory Rate<br />
LED Numeric Display<br />
• CO2 Bar Graph<br />
14 segment LED bar graph<br />
ConTrolS<br />
• Power<br />
ON key<br />
• Alarm Silence<br />
2 min. alarm silence key (WW8110-001 only)<br />
• ETCO 2<br />
Up/Down key for setting alarm limits<br />
(WW8110-001 only)<br />
Capnocheck ® <strong>Capnometer</strong> and Accessories<br />
Capnocheck ® <strong>Capnometer</strong> with Alarms (mmHg)......... WW8110-001SYS<br />
Capnocheck ® <strong>Capnometer</strong> (mmHg)............................... WW8110-000SYS<br />
Airway Adapter, box of 25................................................ WW8111<br />
Lanyard.............................................................................. WW8121<br />
Carrying Case................................................................... WW8120<br />
Airway Adapter Lanyard<br />
Carrying Case<br />
<strong>Smiths</strong> <strong>Medical</strong> PM, inc.<br />
Patient Monitoring and Ventilation<br />
N7W22025 Johnson Drive, Waukesha, Wisconsin 53186 USA<br />
Phone: 262-542-3100 Fax: 262-542-0718 Toll-Free: 800-558-2345<br />
www.smiths-medical.com/capnocheck<br />
<strong>Smiths</strong> <strong>Medical</strong>, part of the global technology business <strong>Smiths</strong> Group<br />
Product(s) described may not be licensed or available for sale outside of the United States.<br />
BCI, Capnocheck, Pneupac and the <strong>Smiths</strong> <strong>Medical</strong> design mark are trademarks of the <strong>Smiths</strong> <strong>Medical</strong> family of companies.<br />
The symbol ® indicates the trademark is registered in the U.S. Patent and Trademark Office and certain other countries.<br />
All other names and marks mentioned are the trade names, trademarks or service marks of their respective owners.<br />
© 2009 <strong>Smiths</strong> <strong>Medical</strong> family of companies. All rights reserved. BC2036 Rev.02 08/09<br />
Co2<br />
• Range<br />
0 - 99 mmHg (1)<br />
• Accuracy<br />
0-40 mmHg ± 2 mmHg, 41-99 mmHg 6%<br />
(2) (3)<br />
of reading, during standard conditions<br />
• Rise Time<br />
< 60 ms<br />
• Total System Response Time<br />
< 0.5 sec.<br />
noTeS<br />
(1) Gas reading showing actual partial pressure at<br />
current humidity level.<br />
(2) To include quantitative effect on gas reading<br />
from variations in environment conditions<br />
and presence of N2O, anesthetic agents,<br />
Ethanol, Isopropyl alcohol, He, Acetone and<br />
Methane, then the CO2 accuracy range should<br />
be increased to ±4 mmHg or 10% of reading,<br />
whichever is the greater.<br />
(3) CO2 was tested at a RR of 40. As RR rates<br />
increase above 60, the accuracy range will<br />
also increase.<br />
Information subject to change without notice. Please read the Instructions For Use supplied with the product for detailed instructions, warnings and cautions.<br />
For more information, please call <strong>Smiths</strong> <strong>Medical</strong> PM, Inc. at 262-542-3100 or 800-558-2345 or your <strong>Smiths</strong> <strong>Medical</strong> distributor.